Michael S. Waring, Ph.D.

Assistant Professor

 

Civil, Architectural and Environmental Engineering

Drexel Univeristy

3141 Chestnut St., AEL 273-B

Philadelphia, PA 19104

 

Phone: 215.895.1502

Fax: 215.895.1363

Email: msw59 (at) drexel [dot] edu


    Research

    Education

    Courses

    Publications

    Other



Research

  • Indoor air quality
  • Indoor particulate matter fate and transport
  • Indoor chemistry and particle formation
  • Secondary impacts of control technologies


Education

  • Ph.D., University of Texas at Austin, Civil Engineering, 2009
  • M.S., University of Texas at Austin, Environmental Engineering, 2006
  • B.S., University of Texas at Austin, Architectural Engineering, 2005
  • B.A., University of Texas at Austin, English (special honors) & Economics, 2000


Courses

  • ENVE 550: Indoor Air Quality

  • AE 220: Introduction to HVAC

  • CIVE 320: Fluid Flow


Publications
 

Papers in Refereed Journals

  • Waring, M.S. and Siegel, J.A. 2009. “Influence of HVAC system parameters on indoor secondary organic aerosol concentrations.” ASHRAE Transactions. In Press.

  • Waring, M.S. and Siegel, J.A. 2008. “Particle loading rates for HVAC filters, heat exchangers, and ducts.” Indoor Air, 18, 209-224.

  • Waring, M.S., Siegel J.A., and Corsi, R.L. 2008. “Ultrafine particle removal and generation by portable air cleaners.” Atmospheric Environment, 42, 5003-5014.

  • Waring, M.S. and Siegel, J.A. 2007. “An evaluation of the indoor air quality in bars before and after a smoking ban in Austin, TX.” Journal of Exposure Science and Environmental Epidemiology, 17, 260-268.

Papers in Refereed Conference Proceedings

  • Waring MS, Siegel JA. 2009. The influence of HVAC systems on secondary organic aerosol formation. Healthy Buildings Conference, Syracuse, NY, USA, paper ID 727.

  • Waring, M.S., Siegel, J.A., Morrison, G.C. and Corsi, R.L. 2008. “Indoor secondary organic aerosol formation due to ozone/terpene surface reactions.” AAAR Conference 2008, Orlando, FL.

  • Waring, M.S. and Siegel, J.A. 2008 “Indoor air quality implications of using ion generators in residences.” Indoor Air Conference 2008, Copenhagen, Denmark.

  • Waring, M.S., Siegel, J.A., Corsi, R.L., and Morrison, G.C. 2008 “Do surface reactions influence formation of secondary organic aerosol?” Indoor Air Conference 2008, Copenhagen, Denmark.

  • Waring, M.S., Siegel, J.A. and Corsi, R.L. 2007. “Ultrafine particle removal and generation by portable air cleaners.” Conference of International Society for Exposure Analysis 2007.

  • Waring, M.S., Siegel, J.A. and Corsi, R.L. 2007. “Indoor air quality and exposure implications of using an ion generator in a residential environment.” Conference of International Society for Exposure Analysis 2007.

  • Siegel J.A., Waring M.S., Yu X., and Corsi R.L. 2007. “Do ion generators have a role in sustainable indoor environments?” ASHRAE IAQ Conference 2007.

  • Siegel, J.A., Waring, M.S., Yu, X., and Corsi, R.L. 2006. "Indoor air quality implications of portable ion generators." A&WMA Specialty Conference on Indoor Environmental Quality – Problems, Research, and Solutions, Research Triangle Park, North Carolina (July 2006) 1:1-12.

  • Waring, M.S. and Siegel, J.A. 2006. “An evaluation of a smoking ban ordinance in bars in Austin, TX” Healthy Buildings Conference 2006, Lisbon, Portugal, I, 137-142.

Dissertation

Indoor Secondary Organic Aerosol Formation: Influence of Particle Controls, Mixtures, and Surfaces (Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin)


Other

  • Coming soon...