SELECTED PUBLICATIONS (updated June 2008)

 

PUBLICATIONS 

 

 

ANTI-FOULING TECHNOLOGY FOR HEAT EXCHANGERS

 

Y.I. Cho and S.M. Cho, Heat Exchange Technology, Kirk-Other Encyclopedia of Chemical Technology, 4th ed., Vol. 12, pp.950-990, (1994).

 

E. Choi and Y.I. Cho, Local friction and heat transfer behavior of water in a turbulent pipe flow with a large heat flux at the wall, ASME Trans., J. Heat Transfer, Vol.117, pp.533-539, (1995).

 

In Gyu Park, B.C.Pak, and Y.I.Cho, A Numerical Study of Impingment Heat Transfer in a Confined Circular Jet, KSME International Journal, Vol.11, No.3, pp.348-358, 1997.

 

Chunfu Fan and Y.I. Cho, A new electronic descaling method to control precipitation fouling, submitted to the 1997 National Heat Transfer Conference, Baltimore, August, 1997.

 

Y.I. Cho, Chunfu Fan and Byung-Gap Choi, Theory of Electronic Descaling Technology of Control Precipitation Fouling in Heat Exchangers, Int. Comm. Heat Mass Transfer, Vol.24, 747-756, 1997.

 

Chunfu Fan and Y.I. Cho, Microscopic observation of calcium carbonate crystallization induced by an electronic descaling technology, Int. Comm. Heat Mass Transfer, Vol.24, 757-770, 1997.

 

Y.I. Cho, Byung-Gap Choi, and Bennat J. Drazner, Use of Electronic Descaling Technology to Control Precipitation Fouling in Plate-and-Frame Heat Exchangers, " Compact Heat Exchangers for the Process Industries, (edited by R.K.Shah) pp.267-273, Begell House, New York, 1997. 

 

Y. I. Cho, Byung-Gap Choi, and Bennat J. Drazner, Electronic Anti-Fouling Technology to Mitigate Precipitation Fouling in Plate-and-Frame Heat Exchangers, Int. J. Heat Mass Transfer Vol.41, pp.2565-2571, 1998.

 

Y. I. Cho, Chunfu Fan and Byung-Gap Choi, Use of Electronic Anti-Fouling Technology with Filtration to Prevent Fouling in a Heat Exchanger, Int. J. Heat Mass Transfer, Vol.41, pp.2961-2966, 1998.

 

Y. I. Cho and Byung-Gap Choi, Effect of Fouling on Temperature Measurement Error and a Solution, Journal of Heat Transfer, Vol.120, pp.525-528, 1998.

 

Y. I. Cho and Byung-Gap Choi,Validation of an Electronic Anti-Fouling Technology in a Single-Tube Heat Exchanger, International Journal of Heat and Mass Transfer, Vol.42, pp.1491-1499, 1999..

 

Y. I. Cho and Byung-Gap Choi, Experimental Validation of Electronic Anti-Fouling Technology with a Plate Heat Exchanger, Proceedings of 11th IHTC, Vol.6, pp. 197-201, Kyungju, Korea.

 

Rong Liu and Y.I. Cho, Combined Use of an Electronic Antifouling Technology and Brush Punching for Scale Removal in a Water-Cooled Plain Tube, Experimental Heat Transfer, Vol.12, pp.203-213, 1999.

 

Y.I. Cho and Rong Liu, Control of fouling in a spirally-ribbed water chilled tube with electronic anti-fouling technology, Int. J. Heat Mass Transfer, Vol. 42, pp.3037-3046, 1999.

 

Y.I. Cho and W.T. Taylor, An innovative electronic descaling technology for scale prevention in a chiller, Ashrae Transaction: Symposia Vol. 105, Part 2, SE-99-3-1, pp. 581-586, 1999.

 

W.T.Kim and Y.I.Cho, Experimental study of the crystal growth behavior of CaCO3 fouling using a microscope, Experimental heat Transfer, 13: 153-161, 2000

Y.I. Cho, R. Liu, W.J. McFarland, and L. Fusegni, Study of scale-removal methods in a double-pipe heat exchanger, Heat Transfer Engineering, 21:50-57, 2000

S.H.Lee, Y.I.Cho, C. Bai, D.J.Cho, The effect of aspect ratio on turbulent flow heat transfer and pressure drop in a plate heat exchanger, Int Journal of Heat Exchangers, 1: 113-124, 2000.

W.T.Kim, Y.I.Cho, and C. Bai, Effect of electronic anti-fouling treatment on fouling mitigation with circulating cooling tower water, International Communications in Heat and Mass Transfer, 28: 671-680, 2001

W.T.Kim, C. Bai, and Y.I.Cho, A study of fouling with a microscopic imaging technique, International Journal of Heat and Mass Transfer, 45: 597-607, 2002.

W.T.Kim and Y.I.Cho, A study of scale formation around air bubble attached on a heat transfer surface, Int. Comm. Heat Mass Transfer, 29: 1-14, 2002.

 

S.H. Lee and Y.I. Cho, Velocity effect on electronic-antifouling technology to mitigate mineral fouling in enhanced-tube heat exchanger, Int Journal of Heat Mass Transfer, 45: 4163-4174, 2002.

 

SungHyuk Lee and Young I Cho, Study of the performance of physical water treatment with a solenoid coil to prevent mineral fouling Part 1: Effect of a side-stream filtration, Int. Comm. Heat Mass transfer, Vol. 29, pp.145-156, 2002

 

SungHyuk Lee and Young I Cho, Study of the performance of physical water treatment with a solenoid coil to prevent mineral fouling Part 2: Effect of air bubbles, Int. Comm. Heat Mass transfer, Vol. 29, pp.157-163, 2002

 

Young I Cho , SungHyuk Lee, Wontae Kim, and Sangho Suh, Physical Water Treatment for the Mitigation of Mineral Fouling in Cooling-Tower Water Applications, Fouling in Heat Exchanger Conference, Santa Fe, New Mexico, May 2003

 

Y.I. Cho, S.H. Lee and W. Kim, Physical water treatment for the mitigation of mineral fouling in cooling-tower water applications, Ashrae Transactions, Vol.109, Part 1, pp.346-357, 2003.  Also presented at Ashrae Meeting at Chicago, Jan. 2003.

 

Chiranjeev S. Kalra, Mikhail Kossitsyn, Kamilla Iskenderova, Alexandre Chirokov, Young I. Cho, Alexander Gutsol, Alexander Fridman, Electrical discharges in the Reverse Vortex Flow – Tornado Discharges, ISPC 16, Taormina, Italy, June 22-27, 2003

 

C. S. Kalra, Y. I. Cho, A. Gutsol, A. Fridman, T. S. Rufael, V. A. Deshpande, “Plasma Catalytic Conversion of Methane in Ultra Rich Flame using Transient Gliding Arc Combustion Support ”. – Electronic Proceedings of 2004 Technical Meeting, Central States Section, The Combustion Institute, 21-23 March 2004, University of Texas at Austin, Texas. A35.pdf

 

Young I. Cho, Sung-Hyuk Lee, Wontae Kim, and Sangho Suh, Physical water treatment for the mitigation of mineral fouling, Int. J. Transport Phenomena, Vol. 6, pp.1-6, 2004.

 

Y. Cho, A. Fridman, W. Kim and S. Lee, Physical Water Treatment for fouling prevention in heat exchangers, Advances in Heat Transfer, Academic Press, Vol.38, pp.1-72, 2004.

 

John Lane, Y.I. Cho and W.T. Kim, Pulsed power water treatment as a green scale inhibitor for HVAC and once-through industrial systems,  NACE Paper number 04541, Corrosion-2004 International Conference, 2004.

 

C. S. Kalra, Y. I. Cho, A. Gutsol, A. Fridman, T. S. Rufael, “Gliding arc in tornado using a reverse vortex flow”. Review of Scientific Instruments, 76, 025110 (2005) (7 pages).

 

Young I. Cho and Sung-Hyuk Lee, Reduction in the Surface Tension of Water due to Physical Water Treatment for Fouling Control in Heat Exchangers,  Int. Comm. Heat Mass Transfer, Vol.32, pp.1-9, 2005.

 

4. T Israeli, A Reddy, Y.I. Cho, Investigation on the use of nanofluids to enhance heat pipe performance, ISEC2005-76247, International Solar Energy Conference, Orlando, FL

 

Shon CH, Kim CS, Moon SY, Cho YI, Effect of longitudinally positioned solenoid coil on electronic descaling, Int. Comm. Heat Mass Transfer, Vol. 32, pp.240-247, 2005

 

Y. Cho, J. Lane, and W.T. Kim., Pulsed-power treatment for physical water treatment, Int. Comm. Heat Mass Transfer, Vol. 32, pp.861-871 2005

 

MY Jung, CS Kim, LD Tijing, BC Pak, YI Cho, A study of the onset of biofouling using quartz crystal nanobalance, Int. Comm. Heat Mass Transfer, Vol. 33, pp.7-13, Jan. 2006.

GJ Lee, LD Tijing, BC Pak, BJ Baek, YI Cho, Use of catalytic materials for the mitigation of mineral fouling, Int. Comm. Heat Mass Transfer, Vol. 33, 14-23, Jan. 2006.

 

Young I. Cho, Won Tae Kim and Daniel J. Cho, Electro-flocculation mechanism of physical water treatment for the mitigation of mineral fouling in heat exchangers, Experimental Heat Transfer, Volume 20 Issue 4, 323-335, 2007

 

Leonard D. Tijing, BC Pak, B.J. Baek, and Dong Hwan Lee, Y.I. Cho, An experimental study on the bulk precipitation mechanism of physical water treatment for the mitigation of mineral fouling, Int. Comm. Heat Mass Transfer, 2007, 34, pp.673-681.

 

YI Cho, A Fridman, A Gutsol, Non-thermal plasma for air and water treatments, , submitted to Advances in Heat Transfer.

 

Cho YI and McLachlan, Physical Water Treatment for Cooling Towers, Cooling Technology Institute Annual Conference, Houston TX Feb 4-7, 2008, Paper No. TP08-15

 

 

Leonard D. Tijing, BC Pak and Dong Hwan Lee, Y.I. Cho, Heat-treated titanium balls for the mitigation of mineral fouling in heat exchangers,  Experimental Heat Transfer, Volume 21 Issue 2, pp. 115-132, 2008

 

 

 

 

BIOFLUIDS

 

Y.I. Cho and L.H. Back and  D.W. Crawford, "Pressure Difference-Flow Rate Variation in a Femoral Artery Branch Casting of Man for Steady Flow", ASME Transaction Journal of Biomechanical Engineering, Vol.105, pp.258-262, (1983).

 

Y.I. Cho, L. H. Back, D.W. Crawford and R. F. Cuffel, "Experimental Study of Pulsatile and Steady Flow Through a Smooth Tube and an Atherosclerotic Coronary Artery Casting of Man", Journal of Biomechanics, Vol.16, pp.933-946 (1983).

 

Y.I. Cho and L.H. Back, "A Study of Flow Separation in a Femoral Artery Branch Casting of Man for Steady Flow", Proc. of the 36th ACEMB, Paper No. 25.3 p. 118, Columbus, Ohio, 1983.

 

Y.I. Cho and L. H. Back,"Reynolds Number Effects on the Local Pressure Rise in 30 and 60 Degree Arterial Branch Models for Steady Flow,"  1983 Advances in Bioengineering, pp. 54-55, ASME WAM held at Boston, MA, November, l983.

 

Y.I. Cho and  L.H. Back, "In Vitro Flow Measurements in Ion-Sputtered Hydrocephalus Shunts", Proc of the 36th ACEMB, Paper No. 31.4, p. 152, Columbus, Ohio, 1983.

 

Y.I. Cho, and L.H. Back, "Pressure Distributions and Flow Separation in an Arterial Branch Model for Steady Flow", Proceedings of the 1983 ASME Biomechanics Symposium, AMD-Vol. 56,FED-Vol.l pp.171-174, June 1983.

 

L. H. Back, Y.I. Cho, D.W. Crawford and R. F. Cuffel, "Effect of Mild Atherosclerosis on Flow Resistance in a Coronary Artery Casting of Man", ASME Transaction Journal of Biomechanical Engineering, Vol.106, pp.48-53, (1984).

 

Y.I. Cho, L.H. Back, D.W. Crawford and D.H. Blankenhorn, "Curvature Effect in a Femoral Artery Flow Model of Man", Proc. of the 37th ACEMB, Paper No. 7.5, p. 46, Los Angeles, CA. 1984.

 

Y.I. Cho, L.H. Back, and D.W. Crawford, "Effect of Simulated Hyperemia on the Flow Field in a Mildly Atherosclerotic Coronary Artery Casting of Man," Aviation, Space and Environmental Medicine (Aerospace Medical Society Journal), Vol.56, pp.212 -219 (1985).

 

M.R. Back, Y.I. Cho, and L.H. Back, "Fluid Dynamic Study in a Femoral Artery Branch Casting of Man with Upstream Main Lumen Curvature for Steady Flow," ASME Transaction Journal of Biomechanical Engineering, Vol.107, pp. 240-248, (1985).

 

Y.I. Cho, L.H. Back, and D.W. Crawford, "Experimental Investigation of Branch Flow Ratio, Angle, and Reynolds Number on the Pressure and Flow Fields in Arterial Branch Models," ASME Transaction Journal of Biomechanical Engineering, Vol.107, pp.257-267, (1985).

 

L.H. Back, J.R. Radbill, Y.I. Cho, and D.W. Crawford, "Measurement and Prediction of Flow through an Axisymmetric Replica of a Mildly Atherosclerotic Coronary Artery of Man," Journal of Biomechanics, Vol.19, pp.1-17,(1986).

 

L.H. Back, Y.I. Cho and D.W. Crawford, "Phasic and Spatial Pressure Measurements in a Femoral Artery Branch Model for Pulsatile Flow", ASME Transaction, Journal of Biomechanical Engineering,  Vol.108. pp 251-258, (1986).

 

M.R. Back, Y. I. Cho, D.W. Crawford and L.H. Back," Fluid Particle Motion and Lagrangian Velocities for Pulsatile Flow through a Femoral Artery Branch Model"  ASME Transaction, Journal of Biomechanical Engineering, Vol.109, pp.94-101 (1987).

 

L.H. Back, Y.I. Cho, D.W. Crawford and D.H.Blankenhorn, "Flow Resistance in Curved Femoral Artery Models of Man for Steady Flow",  ASME Transaction, Journal of Biomechanical Engineering, Vol.109, pp.90-93 (1987).

 

Y.I. Cho, Numerical Studies of Arterial Branch Flows with Tapered or Bent Downstream Main Lumen, ASME 1988 Advances in Bioengineering, BED-Vol.8, (edited by G.R.Miller), pp.31-34, 1988.

 

Y.I. Cho and L.H. Back, In Vivo Flow Measurements in Ion Sputtered Hydrocephalus Shunts, J. Biomechanics, Vol.22, pp.335-342 (1989).

 

Y.I. Cho, Hemodynamics of Arterial Flows, Proceedings of the US-Korea Fluid Engineering

Engineering:Korea-U.S. Progress" ed. by J.H.Kim, Hemisphere, pp. 591-606, New York, 1991.

 

Y.I. Cho and K. Kensey, Effects of the Non-Newtonian Viscosity of Blood on Hemodynamics of Diseased Arterial Flows, presented at the 1989 Winter Annual Meeting, San Francisco, December, 1989: published in the 1989 Advances in Bioengineering, 1989; BED-VOL. 15: 147-148.

 

Y.I. Cho and K. Kensey, The Bolus Theory for the Etiology of Atherosclerosis,  Proceedings of the First World Congress of Biomechanics,  Vol. 2, p. 360, San Diego, CA, September 1-4, 1990.

 

Y.I. Cho, C. Gonzalez, H.V. Ortega, and Moret, Flow Analysis of the Origin and Progression of Intracranial Aneurysm, presented at the 28th Annual Meeting of the American Society of NeuroRadiology, March, 1990, Los Angeles.

 

C. Gonzalez, Y.I. Cho, H.V. Ortega, and J. Moret,  Modeling of the Flow Changes Produced by Balloon Occlusion of Intracranial Aneurysm,  presented at the 28th Annual Meeting of the American Society of NeuroRadiology, March, 1990, Los Angeles.

 

H.V. Ortega, C. Gonzalez, Y.I. Cho, and P. Sommers, Hemodynamic Data from MRA Angio Imaging using Computer Simulation, presented at the 1990 RSNA (Radiological Society of North America) Annual Meeting, Chicago, IL., Nov. 20, 1990.

 

C. Gonzalez, Y.I. Cho, H.V. Ortega, and J. Moret, Flow Analysis of Neurovascular Lesions using Computer Simulations, presented at the 1990 RSNA (Radiological Society of North America) Annual Meeting, Chicago, IL., Nov. 20, 1990.

 

P.F. Reyes, C. Gonzalez, Y.I. Cho, and H.V. Ortega, Modeling in Human Intracranial Aneurysm: Physiological, Neuroradiological, and Neuropathological Correlations, presented at the American Neurological Association (ANA) annual meeting held at Atlanta, October 14-17, 1990.

 

C.F. Gonzalez, Y.I. Cho, H.V. Ortega.  Computer modeling in human intracranial aneurysms:  physiological, neuroradiological and neuropathological correlations.  Am Neurological Assoc l990, New Orleans, Louisiana.

 

C.F. Gonzalez, H.V. Ortega, Y.I. Cho.  Estudio Computarizado del Flujo Sanguineo en Estenosis de la Carotida Interna. II Congress of Ibero Latino American Societies of Neuroradiology, Portugal, April l5, l990.

 

Y.I. Cho, H.V. Ortega, C.F. Gonzalez, Moret J.  Flow analysis of the origin and progression of intracranial aneurysm.  First World Congress in Biomechanics, September l990, San Diego, California.

 

H.V. Ortega, Rifkin MD, Vinitski S. Y.I. Cho, Summers P. Hemodynamic data from MR angiographic imaging using computer simulation.  RSNA Chicago, Illinois, November 28, l990.

 

Y.I. Cho and K.R. Kensey, Bolus theory as the etiology of atherosclerosis, 1990 Advances in Bioengineering, BED-Vol. 17, 265-268, 1990.   also presented at the ASME Winter Annual Meeting held at Dallas, Nov. 25-30, 1990.

 

T.A. Tasciyan, R. Banerjee, Y.I. Cho, and M. Shapiro, Could Hemodynamic Analyses be Helpful in Predicting Blood Flow Signal Levels in MRI?, presented at the 13th Annual Int. Conf., IEEE, Eng. in Medicine and Biology Society, Oct. 31- Nov. 3, 1991, Orlando, FL.

 

R.K. Banerjee, Y.I. Cho and K. Kensey, Effect of the Non-Newtonian Viscosity of Blood on Steady and Pulsatile Flow in Stenosed Arteries, Proceedings of the ASME Winter Annual Meeting, BED-Vol. 20, pp. 103-106, Atlanta, Dec. 4-8, 1991.

 

Y.I. Cho and K. R. Kensey, Effects of the Non-Newtonian Viscosity of Blood on Hemodynamics of Diseased Arterial Flows: Part 1, Steady Flows, Biorheology, Vol.28, pp.241-262, (1991).

 

C. Gonzalez, Y.I. Cho, H.V. Ortega, and J. Moret, Flow Analysis of the Origin and Progression of Intracranial Aneurysms, The American Journal of Neuroradiology, Vol. 13, pp.181-188 (1992).

 

R. Banerjee, Y.I. Cho, and L.H. Back, Pressure drop in a tapered femoral artery of a dog: pulsatile flow, presented at the 1992 Winter Annual Meeting held at Anaheim, CA, November, 1992.  ASME Publication, "1992 Advances in Bioengineering", BED-Vol.22, pp. 285-288

 

R. Banerjee, Y.I. Cho, and L.H. Back, Numerical studies of 3-D arterial flows in Double Curved Femoral Artery of Man, presented at the 1992 Winter Annual Meeting held at Anaheim, CA, November, 1992. ASME Publication, "Advances in Finite Element Analysis in Fluid Dynamics," FED-Vol.137, pp.61-68.

 

K. R. Kensey and Y.I. Cho, Protective adaptation hypothesis as the etiology of atherosclerosis, Journal of Invasive Cardiology, Vol. 4, No.9, pp.448-458, (1992).

 

S. Vinitski, H.V. Ortega, F.B. Mohamed, D.G. Mitchell, A.E. Flanders, S.N. Smullens, and Y.I. Cho, Computer simulation on blood flow using short TE magnetic resonance angiography, 14th Annual Int. Conference, IEEE, Engineering in Medicine and Biology Society, Paris, France, Oct. 29 - Nov.1, 1992.

 

R. Banerjee, Y.I. Cho, and L.H. Back, Numerical studies of 3-D arterial flows in reverse curvature geometry: Part I, steady flow, ASME Transactions, the Journal of Biomechanics, Vol.115, pp.316-326 (1993).

 

T.A. Tasciyan, R. Banerjee, Y.I. Cho, and R. Kim, Two-dimensional pulsatile hemodynamic analysis in the magnetic resonance angiography interpretation of a stenosed carotid arterial bifurcation, Medical Physics , Vol.20(4), pp.1059-1070, (1993).

 

R. Banerjee, Y.I. Cho, and L.H. Back, Numerical studies of non-Newtonian pulsed flow in a femoral branched vessel, presented at The Fluid Engineering Conference, held at Washington, D.D., June 20-24, 1993.  ASME Publication, FED-Vol. 157, 229-238.

 

T.A. Tasciyan, R. Banerjee, and Y.I. Cho, A Comparison of 2D Pulsatile Hemodynamic Analysis within a Stenosed Carotid Arterial Bifurcation and its Normal Counterpart,  ASME Publication, FED-Vol. 157, pp.221-228.

 

K.R. Kensey and Y.I. Cho, Protective adaptation hypothesis as the etiology of arterial occlusive disease, presented at the Third Annual International Symposium on Invasive Cardiology in the 90's. Monterey, CA., Sept. 1993.

 

K.R. Kensey and Y.I. Cho, Protective adaptation to chronic mechanical injury as the etiology of arterial occlusive disease, Annuals of Biomedical Engineering, Vol.21, Suppl.1, p. 28, 1993. presented at the Biomedical Eng. Society, 25th Anniversary 1993 Fall Annual Meeting, Memphis, TN, Oct. 1993.

 

R.K. Barnejee, Y.I. Cho and K.R. Kensey, AMPPULSE theory as the etiology of atherosclerosis in branched vessels, Advances in Bioengineering, BED-Vol.26, pp. 71-74, 1993.  Also presented at the 1993 ASME Winter Annual MEeting held at New Orleans, Nov. 28-Dec. 3, 1993.

 

K.R. Kensey and Y.I. Cho, A theory implicating the protective adaptation to chronic mechanical injury as the etiology of arterial occlusive disease, the Journal of Invasive Cardiology, Vol. 6, No.2, pp.55-70, (1994).

 

K.R. Kensey and Y.I. Cho, Protective adaptation to chronic mechanical injury as the etiology of arterial occlusive disease, presented at the 6th International Symposium on Transcatheter Cardiovascular Therapeutics, Washington Cariology Center, Washington D.C., Feb. 24-27, 1994.

 

J. Benson, G.Magram, W. Cho, and Y.I. Cho, Prevention of overdrainage using a capacitor in hydrocephalus shunts, BED-Vol.28, 1994 Advances in Bioengineering, ASME 1994, pp.97-98, 1994.

 

W.L.Cho, S.Y. Kim, Y.I.Cho and K.Kensey, A study of passive balloon system to control hypertention, Advances in Bioengineering, BED-Vol.26, 447-450, 1993.  Also presented at the 1993 ASME Winter Annual Meeting held at New Orleans, Nov. 28-Dec. 3, 1993.

 

R. Banerjee,  L.H. Back, Y.I. Cho, Flow-pressure drop measurement and calculation in a tapered femoral artery of a dog, Biorheology, Vol. 32, 655-684, 1995.

 

R. Banerjee,  C. Gonzalez, Y.I. Cho, and Luc Picard, Hemodynamic changes in recurrent intracranial terminal aneurysm after endovascular treatment, Acad Radiology, Vol. 3: 202-211, (1996).

 

H.V. Ortega, C.F. Gonzalez, and Y.I. Cho, Computer Simulation Blood Flow Analysis and Color Doppler Studies of Experimental Aneurysms: A Correlative Study.  AIUM (American Institute in Ultrasound in Medicine), Atlanta, GA, Feb. 24-27, 1991.

 

H.V. Ortega, C.F. Gonzalez, and Y.I. Cho, Computer Flow Analysis of Experimental Arteriovenous Fistula and Small Aneurysms.  39th Annual Meeting, Association of University Radiologists, Orlando, FL., March 17-22, 1991.

 

H.V. Ortega, S. Vinitski, and Y.I. Cho, Computer Simulation of Blood Flow Using Short TE Time of Flight and Phase Contrast MRA.  39th Annual Meeting, Association of University Radiologists, Orlando, FL., March 17-22, 1991.

 

S. Vinitski, H.V. Ortega, and Y.I. Cho, Study of Arterial Flow from Magnetic Resonance Angiography using Computer Simulation, presented at the 9th Annual Meeting of the Society for Magnetic Resonance Imaging, Chicago, IL, April 13-17, 1991.

 

West FW, H.V. Ortega, Rush MP, Y.I. Cho.  Computer simulation of hemodynamic parameters at the location of plaque formation with Doppler ultrasound correlation.  AIUM, Atlanta, Georgia, February 24-27,  l99l.

 

Northrup BE, C.F. Gonzalez, H.V. Ortega, Consigny PM, Goldberg BB, Y.I. Cho.  Coil induced thrombosis in artificial aneurysm:   color Doppler and computer simulated blood flow analysis.  Am Assoc. Neurological Surgeons, New Orleans, Louisiana, April 20-25, l99l.

 

K.R. Kensey and Y.I. Cho, Effects of Whole Blood Viscosity on Atherogenesis, the Journal of Invasive Cardiology, Vol. 9, No.1, pp.17-24, (1997).

 

R. Banerjee, Y.I. Cho, and K.R. Kensey, A study of local hydrodynamics in a 90o branched vessel with extreme pulsatile flows, Int. J. CFD, Vol.9, pp.23-42, 1997.

 

R. Banerjee, L.H. Back, and Y.I. Cho, Catheter Obstruction Effect on Pulsatile Flow Rate – Pressure Drop During Coronary Angioplasty, ASME Bioengineering Conference, BED-Vol.35, 1997.

 

R. Banerjee, L.H. Back, M.R. Back, and Y.I. Cho, Catheter Obstruction Effect on Pulsatile Flow Rate – Pressure Drop During Coronary Angioplasty, ASME Journal of Bioengineering Engineering, Vol. 121, pp.281-289, 1999.

 

Y.I. Cho, Wontae Kim, and Ken Kensey, A new scanning capillary tube viscometer, Review of Scientif Instruments, Vol.70, pp.2421-2423, 1999.

 

S. Kim, Y.I. Cho, K.R. Kensey, R.O. Pellizzari, and P.R.H. Stark, A scanning dual-capillary-tube viscometer, Review of Scientific Instruments, 71: 3188-3192, 2000

 

S. Kim, Y.I. Cho, A.H. Jeon, B. Hogenauer, K.R. Kensey, A new method for blood viscosity measurement, Journal of non-Newtonian Fluid Mechanics,  94: 47-56, 2000

 

S. Kim, Y.I. Cho, B. Hogenauer, K.R. Kensey, A method of isolating surface tension and yield stress effects in a U-shaped scanning capillary tube viscometer, Journal of Non-Newtonian Fluid Mechanics, 103: 205-219, 2002.

 

S. Kim and Y.I. Cho, The effect of dye concentration on the viscosity of water in a scanning capillary tube viscometer, Journal of Non-Newtonian Fluid Mechanics, 111: 63-68, 2003

 

 

 

 

 

Back to Top

Back to Home Page

Back to Vitae